Burcam 300608 CAST IRON SUBM. SUMP PUMP MECHANICAL SWITCH Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Bombas Burcam 300608 CAST IRON SUBM. SUMP PUMP MECHANICAL SWITCH. Burcam 300608 CAST IRON SUBM. SUMP PUMP MECHANICAL SWITCH 1/3HP 115V User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 6
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
2190 Boul. Dagenais West TEL: 514.337.4415
LAVAL (QUEBEC) FAX: 514.337.4029
CANADA
INSTALLATION
INSTRUCTIONS
Please read these
instructions
carefully. Failure
to comply to
instructions and
designed
operation of
this system,
may void
the
warranty.
Your pump has been carefully packaged at
the factory to prevent damage during
shipping. However, occasional damage may
occur due to rough handling. C
arefully
inspect your pump for damages that could
cause failures. Report any damage to your
carrier or your point of purchase.
MODEL
300608
SUBMERSIBLE
SUMP PUMP
MONTHLY MANDATORY CHECK-UP:
1. Inspect the pump and the sump for any
obvious condition that necessitates
cleaning, correction, adjustement or repair.
2. Clear the sump and the surroundings of
any paper, leaves or other debris that
might clog the input openings. Remove
anything that might float into the sump.
3. Assure that the pump is secure and
vertical for proper operation.
4. Assure that there is adequate clearance
from any combustible materials or
structure. Stored materials must be kept
away from the pump. Shelves or cabinet
structures must not be in close proximity
over the pump.
5. Assure that the motor is securely plugged
into a proper GFCI electrical outlet.
6. Test the ‘GFCI’ outlet by pressing its test
switch. This should prove that the outlet is
energized and will trip off to protect against
a ground fault. Be sure to reset the ‘GFCI’
by pressing its reset switch.
7. Lift the float to prove that the pump will
start when required. (Step 8 below will test
submersible pumps with enclosed floats).
8. Put a pail of water (8 liters) in the sump to
prove that any check valve present will
permit effluent to flow.
9. Observe that the plumbing can carry the
effluent safely out of the residence.
WWW.BURCAM.COM
© 2012 BUR-CAM Printed in Canada 310824
Vista de página 0
1 2 3 4 5 6

Resumo do Conteúdo

Página 1 - INSTRUCTIONS

2190 Boul. Dagenais West TEL: 514.337.4415LAVAL (QUEBEC) FAX: 514.337.4029CANADAH7L 5X9 [email protected]

Página 2 - SAFETY INSTRUCTIONS:

SAFETY INSTRUCTIONS:This fine pump that you have just purchased is designed from the latest in material and workmanship.Before installation and operat

Página 3 - INSTALLATION STEPS

3APPLICATIONThis submersible sump pump is designed for apermanent sump installation. To be used in a residential cottage and farm application.CA

Página 4 - SUMP PUMP APPLICATION

4At this step, you have the opportunity to install a 1 1/2” or a 1 1/4” discharge. We recommenda 1 1/2” ABS/DWV discharge. Install a check valve (350

Página 5 - REPAIR PARTS

Repair parts may be ordered from your authorized point of sale or fromBUR-CAM PUMPSREPAIR PARTSSTEP 2Sump pit 18” diameter X25” depthSTEP 3Prepare you

Página 6

6TROUBLE SHOOTING GUIDE CHECKLISTNEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWERCONNECTED. DON’T JUST UNSCREW THE FUSE OR

Comentários a estes Manuais

Sem comentários